-40%

ETCR5000 3 Phase Power Quality Analyzer Meter with ETCR040B Current Clamp Sensor

$ 1161.59

Availability: 100 in stock
  • All returns accepted: Returns Accepted
  • Expert mode: Yes.
  • Condition: New
  • Frequency: 40Hz~70Hz.
  • Length of voltage test wire: 3m.
  • Brand: VTSYIQI
  • Restocking Fee: No
  • Refund will be given as: Money back or replacement (buyer's choice)
  • MPN: ETCR5000+ETCR040B
  • Country/Region of Manufacture: China
  • Energy parameters: Wh, Varh, Vah.
  • Return shipping will be paid by: Buyer
  • Communication: USB.
  • Phase-to-neutral voltage: 1.0V~1000V.
  • Harmonic Order: 0~50.
  • Bandwidth: See description
  • Current Measurement Range: See description
  • Number of TraNumnsient records: 150 sets.
  • Phase Configuration: 3-Phase
  • Maximum Peak Transient Voltage: See description
  • warranty: 1 year
  • Item must be returned within: 30 Days
  • Number of channels: 4U/4I.
  • Phase-to phase voltage: 1.0V~2000V.
  • Voltage Measurement Range: See description

    Description

    ETCR5000 3 Phase Power Quality Analyzer Meter with ETCR040B Current Clamp Sensor
    Note:
    1)This type ETCR5000 comes with 4 PCS  ETCR040B current clamps(
    ETCR
    040B current clamp: 0.10A~100A;Size:35mm * 40MM)
    2)The Sensor of ETCR008B and ETCR068B are optional accessories , The price is different ,  If you need either of the two sensor please contact me by message .
    ETCR5000 Power Quality Analyzer's basic function:
    ◆Transient capture function
    Monitoring instantaneous change of power grid voltage current parameters, including the voltage current fluctu-ations, voltage current surge, sag and short supply interruption, temporary overvoltage, impact current and Cur-rent voltage instantaneous distortion. Instruments can store 150 sets of transient waveform at the same time.
    ◆Starting current monitoring
    Monitoring surge current of line and the startup current when electrical equipment is starting, help to correctly design capacity. Can be display the RMS rising / falling curve In the startup process, the envelope curve of startup current, waveform of 4 channels current and 4 channels voltage. Recording about 100s after trigger, storage the current /voltage instantaneous and waveform curve of each cycle in 100s.
    ◆Trend chart recording and storing function
    Store all the test parameters of basic test functions (Urms, Uthd, Ucf, Uunb, Hz, Vrms, Vthd, Vcf, Vunb, PST, Arms,  Athd, Acf, Aunb, KF,W, VAR, VA, PF, COSφ, TANφ),50 voltage harmonics, 50 current harmonics. And create the trend curve. Record data for a long time according to need(concurrent selection 20 parameters to record data for once every five seconds, you can record about 300 days.).
    ◆Alarm function
    Set the limit values according to need, monitoring the values whether overshoot, if overshoot will generate an alarm log, such as: voltage, current, unbalance, harmonic ratio, frequency, active power, total harmonic distor-tion. You can configure 40 different alarms, each group can set different monitoring parameters (including 50 harmonics, total of 123 different parameters) and limit values, also can set the shortest time of overshoot. The log can contain up to 12,800 alarms.
    ◆Snapshot function
    Any screen can be saved (screen snapshot), at the same time automatically records the time and test mode. Such as can save voltage and current waveform, harmonic bar chart, phasor diagram etc. It can save a maximum of 60 screen snapshot.
    ◆Communication function
    Communicate with computer via USB; Monitoring software can display waveform of power quality analysis, read of the transient waveform, trend chart recording, alarm log, screenshots, and display on the computer.
    ◆Setting function
    The user can configuration of the time and date, configuration of the screen contrast and brightness, definition of each phase curve colors’.
    Choice of type of connection to the net work.
    Configuration of the type of the current sensors and voltage ratios.
    Select Chinese menu or English menu.
    ◆Help menu in Chinese/English
    Every stage of operation can press the "help" key to obtain relevant information.
    Specification:
    Power supply
    Rechargeable lithium-ion battery packs 9.6V, backup charger.
    Battery indicator
    Battery symbol  shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.
    Power consumption
    Current consumption of normal test 490 mA, continuous working for 8 hours.
    Display mode
    LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm.
    Size of current clamp
    040B circle current clamp: 35mm×40mm;
    Instrument dimensions
    L×W×H: 240mm×170mm×68 mm.
    Number of channels
    4U/4I.
    Phase-to phase voltage
    1.0V~2000V.
    Phase-to-neutral voltage
    1.0V~1000V.
    Range of current clamp
    040B current clamp: 0.10A~100A;
    Frequency
    40Hz~70Hz.
    Parameters of electricity
    W, VA, Var, PF, DPF, cosφ, tanφ.
    Energy parameters
    Wh, Varh, Vah.
    Harmonic
    Order 0~50.
    Total harmonic distortion
    Order 0~50, each phase.
    Expert mode
    Yes.
    Number of Transient records
    150 sets.
    Voltage flicker
    Yes.
    Starting current mode
    Yes, 100 seconds.
    3 phases unbalance
    Yes.
    Record
    300 days(simultaneous recording 20 parameters, record one point every 5 seconds).
    Min/Max recorded value
    Measurement of maximum and minimum values over a period of time.
    Alarm
    40 different types of parameter selections, 12,800 sets alarm logs.
    Peak
    Yes.
    Phasor diagram display
    Automatically.
    Capacity of snapshots
    60
    Menu language
    English/Chinese.
    Communication
    USB.
    Automatic switching off
    When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.
    In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.
    Backlight function
    Yes, suitable for use at night and dark place.
    Weight
    Host: 1.6kg (with battery).
    040B circle current clamp: 190g×4;
    Length of voltage test wire
    3m.
    Length of current sensor wire
    2m.
    Working temperature and humidity
    -10°C~40°C; below 80%Rh.
    Storage temperature and humidity
    -10°C~60°C; below 70%Rh.
    Input impedance
    Input impedance of test voltage: 1MΩ.
    Withstand voltage
    Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.
    Insulation
    Between instrument wiring and shell ≥10MΩ.
    Structure
    Double insulation, with insulation vibration-proof sheath.
    Safely rules
    IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.